Motor full load current: converting kW to amps
How to turn a motor's kW rating into amps: the three-phase and single-phase formulas, why efficiency and power factor matter, starting current, and a worked 11 kW, 400 V example.
Read article →Category
How to turn a motor's kW rating into amps: the three-phase and single-phase formulas, why efficiency and power factor matter, starting current, and a worked 11 kW, 400 V example.
Read article →How to work out hydraulic motor torque, speed and power from displacement, pressure drop and flow, size the pump and electric motor, and check a worked 1,200 N·m at 150 rpm drive.
Read article →How to calculate the weight of steel plate, round bar, pipe and hollow section from size and length, with the d²/162 rule, density factors for stainless and aluminium, and a worked 970 kg material list.
Read article →How to estimate welding cost: weld metal weight for fillet and V butt welds, rod or wire to buy, arc time, operating factor, gas and power, with a worked stick vs MIG example.
Read article →How to calculate gear ratio, output speed and torque for a gear pair and a multi-stage gear train, with module, centre distance, tooth force and a worked two-stage 4 kW reducer example.
Read article →How to calculate CNC speeds and feeds: spindle rpm from cutting speed, feed rate from chip load, metal removal rate, chip thinning and cutting power, with a worked 16 mm end mill example in mild steel.
Read article →How to calculate air compressor power from free air delivery and pressure: isentropic and isothermal power, discharge temperature, specific power, motor size and annual energy cost, with a worked 10 m³/min example at 7 bar.
Read article →How to size a roller chain drive: speed ratio and sprocket teeth, pitch diameter, chain speed and pull, the chordal effect, chain length in links and the true centre distance, worked through for a 5.5 kW conveyor drive at 50 rpm.
Read article →How long a steam coil takes to heat a tank, and how big the coil must be: heat required, the batch heating formula, U values, coil area and steam load, worked through for a 10 m³ water tank.
Read article →How to size a solid drive shaft: torque from kW and rpm, the ASME allowable shear stress with the keyway factor, combined bending and torsion, and the angle of twist, worked through for a 15 kW, 100 rpm gearbox shaft.
Read article →How to size a steam pipe from flow and pressure: convert kg/h to volume with steam tables, choose a velocity, check the pressure drop and pick a pipe size.
Read article →How to calculate the wall thickness a pressure pipe needs with Barlow's formula and ASME B31.3, add corrosion allowance and mill tolerance, and choose a schedule.
Read article →