Air compressor power from flow and pressure

How to calculate air compressor power from free air delivery and pressure: isentropic and isothermal power, discharge temperature, specific power, motor size and annual energy cost, with a worked 10 m³/min example at 7 bar.

By Site AdministratorUpdated 8 min read

Most compressor quotations start with two numbers: how much air you need and at what pressure. From those two numbers you can work out the power the compressor will draw, check whether a quoted motor size is sensible, and estimate what the air will cost you every year. This guide walks through the air compressor power calculation step by step, from the ideal thermodynamic power to a realistic motor size, with a fully worked example for a 10 m³/min plant air system at 7 bar.

Diagram of an air compressor taking in 10 m³/min of free air at 1.013 bar absolute and 20 °C and delivering it at 7 bar g (pressure ratio 7.91), driven by a 75 kW motor, with the isentropic power formula and results: ideal power 47.6 kW, shaft power 59.5 kW, electrical input 62.6 kW and single-stage discharge temperature about 256 °C

Step 1: get the flow and pressure on the same basis

Compressor capacity is quoted as free air delivery (FAD): the volume of air the machine delivers, measured back at the inlet conditions (atmospheric pressure and temperature). It is measured to ISO 1217 and is the figure to compare between suppliers. It is not the same as the swept volume of a piston machine, and it is not "normal" or "standard" m³ unless the data sheet says so.

  • FAD is usually given in m³/min, l/s or cfm (1 m³/min = 16.67 l/s = 35.31 cfm).
  • Working pressure is usually given as gauge pressure (bar g or psig). The power formulas need absolute pressure: p (bar a) = p (bar g) + 1.013 at sea level.
  • Add the pressure drop of dryers, filters and pipework to the pressure needed at the tools. If the tools need 6 bar g and the system loses 0.7 bar, the compressor must deliver about 6.7 to 7 bar g.

The pressure ratio is then:

r = p2 / p1 = (p_gauge + 1.013) / 1.013

For 7 bar g at sea level: r = 8.013 / 1.013 = 7.91.

Step 2: the ideal (isentropic) compression power

When air is compressed quickly, without time to lose heat, the process is close to adiabatic. The ideal power for this reversible adiabatic (isentropic) compression is:

P = [k / (k − 1)] × p1 × Q × [r^((k − 1)/k) − 1]

  • P = ideal power, W
  • k = ratio of specific heats, 1.4 for air
  • p1 = absolute inlet pressure, Pa (101,325 Pa at sea level)
  • Q = free air delivery, m³/s
  • r = pressure ratio from Step 1

With k = 1.4 the first term is 3.5 and the exponent is 0.2857. For 1 m³/min (0.01667 m³/s) at 7 bar g:

P = 3.5 × 101,325 × 0.01667 × (7.91^0.2857 − 1) = 3.5 × 101,325 × 0.01667 × 0.806 ≈ 4,760 W

So an ideal single-stage machine needs about 4.76 kW for every m³/min of free air at 7 bar g. No real compressor gets there; the next steps add the losses.

Isothermal power: the lower limit

If the air could be kept at inlet temperature throughout, the work would be lower:

P_iso = p1 × Q × ln(r)

At 7 bar g this gives 101,325 × 0.01667 × ln(7.91) ≈ 3.49 kW per m³/min. Nobody builds an isothermal compressor, but the figure shows how much of the work goes into heating the air.

Two-stage compression with intercooling

Splitting the compression into two stages and cooling the air back to inlet temperature between them brings the work closer to isothermal. With equal ratios per stage (each stage √r):

P_2stage = 2 × [k / (k − 1)] × p1 × Q × [r^((k − 1)/(2k)) − 1]

At 7 bar g that is about 4.06 kW per m³/min, roughly 15% less than single-stage. This is why large reciprocating and oil-free screw compressors are built with two stages and an intercooler.

Step 3: discharge temperature

The same exponent gives the ideal temperature of the air leaving a stage:

T2 = T1 × r^((k − 1)/k) (temperatures in kelvin)

Air entering at 20 °C (293.15 K) and compressed in one stage to 7 bar g would leave at about 293.15 × 1.806 = 529 K, or 256 °C. Oil-injected screw compressors avoid this by injecting oil that absorbs the heat, so they discharge at around 70 to 100 °C before the aftercooler. With two stages and intercooling the ideal outlet temperature of each stage falls to about 121 °C. Either way, nearly all of the input power ends up as heat in the cooling oil, cooling air or water, which is worth knowing when you size compressor room ventilation or plan heat recovery.

Step 4: from ideal power to shaft and electrical power

Real compressors lose energy to friction, leakage inside the element, heating of the inlet air and pressure drops in valves, separators and coolers. These are lumped into an isentropic efficiency:

P_shaft = P_ideal / η_is

P_electrical = P_shaft / η_motor

Typical isentropic (element) efficiencies for well-designed industrial screw compressors are in the 70 to 85% range at full load, and IE3 motors in the 37 to 90 kW range are around 94 to 95% efficient. These are planning values; the supplier's data sheet is the real answer.

Specific power: the number on the data sheet

Manufacturers quote specific power: total package input power (motor, fan and controls) divided by FAD, in kW per m³/min or kW per 100 cfm. CAGI data sheets for oil-injected rotary screw compressors at around 100 psig (6.9 bar g) commonly show about 17 to 20 kW per 100 cfm at full load, which is about 6.0 to 7.1 kW per m³/min. Multiply kW/100 cfm by 0.353 to convert to kW per m³/min.

Specific power is the best single figure for comparing machines, provided they are quoted at the same pressure and with the same scope (package input, not just motor shaft power).

Worked example: air compressor power calculation for 10 m³/min at 7 bar g

A workshop needs 10 m³/min of free air delivered at 7 bar g. The site is near sea level and the intake air is at 20 °C. The compressor runs 4,000 hours a year at full load and electricity costs 0.12 per kWh (use your own currency and tariff).

1. Pressure ratio

r = (7 + 1.013) / 1.013 = 7.91

2. Ideal single-stage power

Q = 10 / 60 = 0.1667 m³/s

P = 3.5 × 101,325 × 0.1667 × (7.91^0.2857 − 1) = 3.5 × 101,325 × 0.1667 × 0.806 = 47.6 kW

For comparison, the isothermal minimum is 34.9 kW and the ideal two-stage figure is 40.6 kW.

3. Shaft power

With an isentropic efficiency of 80%: P_shaft = 47.6 / 0.80 = 59.5 kW

4. Electrical input

With a 95% efficient motor: P_el = 59.5 / 0.95 = 62.6 kW, or about 6.3 kW per m³/min.

5. Cross-check against real machines

At 6.0 to 7.1 kW per m³/min, a real package would draw roughly 60 to 71 kW. The estimate of 62.6 kW sits inside that band, so it is reasonable.

6. Motor size

A 55 kW motor cannot deliver 59.5 kW at the shaft continuously, so the next standard IEC size, 75 kW, is the class to look at. In practice you choose from the supplier's FAD table: pick the model whose FAD at 7 bar g is at least 10 m³/min, not the motor rating alone.

7. Annual energy and cost

Using a package figure of 6.5 kW per m³/min: 65 kW × 4,000 h = 260,000 kWh a year, which costs 260,000 × 0.12 = 31,200 a year. Over a typical service life the electricity costs several times the purchase price of the compressor, which is why specific power matters more than the price tag.

8. Imperial check

10 m³/min = 353 cfm; 7 bar g = 101.5 psig; 65 kW = 87.2 hp. That is 18.4 kW per 100 cfm, or about 4.1 cfm per hp, in line with the common rule of thumb of roughly 4 to 5 cfm per hp for screw compressors at 100 psig.

Bar chart of compressor power for 10 m³/min at 7 bar g: isothermal 34.9 kW, ideal two-stage 40.6 kW, ideal single-stage 47.6 kW, shaft power 59.5 kW and electrical input 62.6 kW, with the 60 to 71 kW band of real screw compressor packages shaded

Why every bar of pressure costs money

Repeating the ideal calculation at 6 bar g instead of 7 bar g gives 43.6 kW instead of 47.6 kW, a saving of about 8.4%. Compressor makers quote a rule of thumb of about 7% energy saved per 1 bar of pressure reduction, and the formula agrees. In the worked example, 8.4% of 260,000 kWh is about 21,800 kWh, or roughly 2,600 a year, for simply not running the system 1 bar higher than the tools need. Lower pressure also reduces the air lost through leaks.

The table below gives the ideal power per m³/min of free air at sea level and 20 °C intake. Divide by your expected efficiency to get shaft power.

Pressure (bar g)
Ratio r
Isothermal (kW per m³/min)
Two-stage ideal (kW per m³/min)
Single-stage ideal (kW per m³/min)
Single-stage T2 (°C)
4
4.95
2.70
3.03
3.42
190
6
6.92
3.27
3.76
4.36
236
7
7.91
3.49
4.06
4.76
256
8
8.90
3.69
4.33
5.13
274
10
10.87
4.03
4.80
5.78
306
13
13.83
4.44
5.38
6.61
348

Common mistakes in compressor power calculations

  • Using gauge pressure in the ratio. 7 / 1 = 7 instead of 8.013 / 1.013 = 7.91 underestimates the power by several per cent.
  • Mixing FAD with demand at pressure. Air tool consumption is normally given as free air. A flow measured in the compressed line must be converted back to free air before you use it.
  • Comparing specific power at different pressures. A machine rated at 7 bar g always looks better than one rated at 10 bar g. Compare at the same pressure.
  • Sizing the motor on ideal power. Ideal power is a lower bound. Always divide by a realistic efficiency or use the data sheet.
  • Ignoring altitude and hot intake air. At altitude p1 is lower, so the ratio for the same gauge pressure is higher, and a compressor delivers less mass of air. Hot intake air also reduces the mass delivered for the same FAD.
  • Forgetting leaks and future demand. Leakage is often a large share of demand in older plants. Measure it before buying a bigger compressor, and size the receiver to smooth peaks; see our guide to sizing a compressed air receiver tank.

Quick reference

  • Pressure ratio: r = (p_gauge + 1.013) / 1.013
  • Ideal single-stage power: P = 3.5 × p1 × Q × (r^0.2857 − 1)
  • Ideal two-stage power: P = 7 × p1 × Q × (r^0.1429 − 1)
  • Isothermal power: P = p1 × Q × ln(r)
  • Discharge temperature: T2 = T1 × r^0.2857 (kelvin)
  • Shaft power = ideal power / isentropic efficiency; electrical power = shaft power / motor efficiency
  • kW per 100 cfm × 0.353 = kW per m³/min
  • About 7 to 8% less energy per 1 bar lower pressure

To check the motor and gearbox side of a drive, use the motor and drive calculator. For converting cfm, l/s, psi and hp, the unit converter saves mistakes, and the pipe flow calculator helps check the pressure drop in the distribution line. The method is similar to the one in our guide to fan power and motor size, but at pressure ratios where the compressibility of air can no longer be ignored. For background on the thermodynamics, see Isentropic process (Wikipedia).

#air compressor#specific power#compressed air#free air delivery#motor sizing#energy cost#compressor power