A compressor that loads and unloads every few seconds wears its inlet valve, contactors and motor, wastes power and gives the plant a pressure that never settles. The usual cure is an air receiver: a pressure vessel between the compressor and the plant that stores air, steadies the pressure and lets the compressor run in longer, calmer cycles. This guide shows how to work out the receiver volume from the compressor output and the pressure band, with two worked examples.

Diagram of a compressor feeding an air receiver with a safety valve and drain, which supplies plant demand between 6.5 and 7.5 bar(g)

A receiver sits between the compressor and the plant and works between the load and unload pressures.

What an air receiver does

  • Stores air for peaks. When demand briefly exceeds what the compressor delivers, the receiver makes up the difference while its pressure falls.
  • Reduces cycling. A bigger volume takes longer to pump up and to draw down, so a load/unload or start/stop compressor switches less often.
  • Steadies pressure. It smooths the pulses from a reciprocating compressor and the swings caused by machines that draw air in bursts.
  • Separates water. Air cools in the vessel, moisture condenses and is drained from the bottom.

A wet receiver sits straight after the compressor, before the dryer, and catches condensate. A dry receiver sits after the dryer, often close to a large intermittent user. Many plants have both, and both count towards storage.

The basic receiver formula

A receiver can only give up air while its pressure falls. If the air stays at roughly the same temperature, Boyle's law gives the volume needed to supply a quantity of free air:

V = Q × t × pa ÷ (p1 − p2)

  • V is the receiver volume, in m³.
  • Q is the free-air flow that has to come from storage, in m³/min. For a peak, it is the demand minus what the compressor is delivering.
  • t is how long that flow lasts, in minutes.
  • pa is atmospheric pressure, absolute: 1.013 bar at sea level.
  • p1 − p2 is the pressure fall you can accept, in bar. Because it is a difference, gauge or absolute readings both work, as long as pa is in the same unit.

Turned around, a receiver holds V × (p1 − p2) ÷ pa of usable free air. A 2 m³ receiver falling from 7.5 to 6.5 bar(g) gives 2 × 1.0 ÷ 1.013 = 1.97 m³, less than half a minute of a 4.2 m³/min compressor's output. Storage is useful, but it is never a substitute for enough compressor capacity.

Sizing for compressor cycling

A load/unload compressor loads when pressure falls to pL and unloads when it reaches pU. The cycles come fastest when the plant uses exactly half of the compressor's output, because filling and emptying then take equal time. Sizing for that worst case gives:

V = C × T × pa ÷ (4 × (pU − pL))

Here C is the compressor's free air delivery (FAD) in m³/min and T is the shortest cycle time the maker accepts, in minutes. Manufacturers usually state this as a maximum number of load cycles or motor starts per hour; start/stop machines are allowed far fewer than load/unload machines. Variable-speed compressors follow demand and can usually work with a smaller receiver, but check the maker's minimum system volume.

Worked example 1: a screw compressor

A compressor delivers 4.2 m³/min FAD, loads at 6.5 bar(g) and unloads at 7.5 bar(g). The maker allows 30 load cycles an hour, so T = 2 minutes.

  • V = 4.2 × 2 × 1.013 ÷ (4 × 1.0) = 8.51 ÷ 4 = 2.13 m³.
  • Choose the next standard size up, for example a 2,500 litre receiver.
  • At half load (2.1 m³/min) a 2.13 m³ receiver takes 1 minute to fill and 1 minute to empty: one cycle every 2 minutes, exactly the limit.

The volume of the receiver piping and any dry receiver also count, so a larger system needs a little less. Widening the band to 2 bar would halve the volume, but every extra bar of unload pressure costs compressor power, so a wider band is rarely the cheaper answer.

Sawtooth chart of receiver pressure rising to 7.5 bar(g) while the compressor is loaded and falling to 6.5 bar(g) while unloaded, one cycle every 2 minutes

Pressure in the receiver rises while the compressor is loaded and falls while it is unloaded.

Sizing for a peak demand

Worked example 2: a short heavy draw

The same plant has a blast cabinet that draws 6.0 m³/min for 3 minutes, while the compressor can give only 4.2 m³/min. Equipment downstream needs at least 6.0 bar(g), so the receiver may fall from 7.5 to 6.0 bar(g).

  • Shortfall = (6.0 − 4.2) × 3 = 5.4 m³ of free air.
  • V = 5.4 × 1.013 ÷ 1.5 = 3.65 m³.

Then check the refill. After the peak the compressor's spare capacity has to put those 5.4 m³ back before the next draw starts. If the large user sits far from the compressor room, place this receiver near it, so the pipeline does not take the pressure drop as well.

Rules of thumb and their limits

An older rule sized receivers at 1 to 3 US gallons per cfm of compressor capacity, roughly 8 to 24 litres per l/s. US Department of Energy training material for compressed air systems notes that this rule came from reciprocating compressors and is no longer considered good practice. Use it only as a sanity check and size from the cycling limit and the real peaks instead.

Practical points

  • A receiver is a pressure vessel. Its design pressure must be above the unload pressure, and it needs a certified safety valve, a pressure gauge and inspection under your local pressure vessel rules.
  • Fit an automatic drain to a wet receiver. The condensate is usually oily water and must be disposed of properly.
  • Keep units consistent: FAD in m³/min, l/s or cfm, and pressures in bar(g) or bar(a). The engineering unit converter and the guide to converting engineering units without mistakes help avoid slips.
  • Once you know the volume, the tank size calculator turns it into a diameter and height for a vertical receiver.

Size the receiver for the worse of the two cases, cycling or peak, round up to a standard size, and confirm the final choice against the compressor maker's recommendations.