Engineering unit conversions that trip people up
How the free engineering unit converter calculates, with worked examples for pressure, torque, power, temperature and maunds, and the conversions it refuses to guess.
On a plant floor the units rarely agree. A pump datasheet gives flow in US gallons per minute, the pressure gauge reads in psi, the motor plate says kW while an old gearbox manual says hp, and grain arrives in maunds. The engineering unit converter takes one value and shows it in every unit of the same quantity at once, so you can read across a table instead of chaining conversions on a phone calculator.
How the calculation works
The tool covers 13 quantities: length, mass, force, pressure and stress, torque, power, energy and work, velocity, area, volume, volumetric flow, angle and temperature. Every unit inside a quantity is stored as a factor against one SI base unit: metres for length, kilograms for mass, pascals for pressure, newton-metres for torque, watts for power, cubic metres per second for flow, and so on. A conversion is then a single line:
result = value × factor of the "from" unit ÷ factor of the "to" unit
Factors are exact wherever the definition is exact: an inch is exactly 0.0254 m, a pound is exactly 0.45359237 kg and a pound-force is exactly 4.4482216152605 N. Results are shown to ten significant figures, and very small or very large results switch to exponential notation so nothing is rounded away to zero.
Temperature is the one exception. Celsius, Fahrenheit, Kelvin and Rankine have different zero points, so a factor alone cannot work. The tool converts through kelvin with an explicit offset: °C + 273.15 gives kelvin, and (kelvin − 273.15) × 1.8 + 32 gives °F.
Worked example: 10 bar to psi. The bar factor is 100,000 Pa and the psi factor is 6,894.757 Pa, so 10 × 100,000 ÷ 6,894.757 = 145.04 psi. Going the other way, 100 psi × 6,894.757 ÷ 100,000 = 6.895 bar.
A few more that come up in a workshop, all as the tool calculates them:
Input | Result | Working |
|---|---|---|
50 N·m | 36.88 lb·ft | 50 ÷ 1.35582 |
15 kW | 20.12 hp (mechanical) | 15,000 ÷ 745.70 |
15 kW | 20.39 PS (metric hp) | 15,000 ÷ 735.50 |
180 °C | 356 °F | 180 × 1.8 + 32 |
100 gpm (US) | 22.71 m³/h | 100 × 3.785412 L × 60 ÷ 1,000 |
10 t | 250 maund (Pakistan) | 10,000 ÷ 40 |
10 t | 267.92 maund (India/Bangladesh) | 10,000 ÷ 37.3242 |
What the tool assumes and leaves out
- It never converts between different quantities. Mass to force, pressure to head of liquid, or volume to mass all need extra physical information such as gravity or the density of the fluid. Rather than quietly assume water at standard gravity, the tool keeps each quantity separate. For pump head, use the pump head and power calculator, which works with the fluid you pump.
- South Asian trade units are listed separately, not merged. The maund is 40 kg in Pakistan but 37.3242 kg under the metric definition used in India and Bangladesh. The seer follows the same split (1 kg in Pakistan, 0.933105 kg in India and Bangladesh), and the tola is 11.6638 g. A 7% gap between two "maunds" is exactly how a delivery quantity goes wrong, so both appear.
- Horsepower comes in two kinds. Mechanical hp is about 745.7 W and metric hp (PS) is about 735.5 W, a difference of roughly 1.4%.
- Some units carry a reference condition. The inch of water is taken at 4 °C, the calorie is the thermochemical calorie (4.184 J), and the gallon is offered as US (3.785 L) and imperial (4.546 L).
- Gauge and absolute pressure are not distinguished. The tool converts the number you type; it does not add or remove atmospheric pressure. A gauge reading stays a gauge reading after conversion.
Common mistakes
- Treating kgf as kg. A kilogram is mass; a kilogram-force is 9.80665 N. In the tool, kgf sits under force and kgf·m under torque, not under mass.
- Mixing up tonnes and tons. The tool lists the metric tonne (1,000 kg), the US short ton (907.18 kg) and the UK long ton (1,016.05 kg). Check which one a foreign drawing or invoice means.
- Converting a temperature difference as a temperature. A rise of 10 °C is a rise of 18 °F, not 50 °F. The converter treats the number as a temperature reading, so for a difference multiply by 1.8 yourself.
- Using the wrong gallon. A US gallon is about 17% smaller than an imperial gallon, and gpm in the flow list means US gallons.
- Rounding too early. Carry the full figure across and round only at the end, especially when the result feeds another calculation such as the pipe size and pressure drop tool.
Open the engineering unit converter, choose the quantity, type the value and read every unit of that family in the table underneath.