Hydraulic motor torque, speed and power from displacement
How to work out hydraulic motor torque, speed and power from displacement, pressure drop and flow, size the pump and electric motor, and check a worked 1,200 N·m at 150 rpm drive.
A hydraulic motor turns oil flow and pressure back into rotation. It drives winches, conveyor and auger drives, mixer drums, wheel and track drives, and the slewing gear of cranes and excavators. Sizing one comes down to three questions: how much torque the load needs, how fast it must turn, and how much flow and pressure the power unit can supply. This guide gives the formulas that connect displacement, pressure drop, flow, torque, speed and power, explains the efficiencies that sit between the theory and the shaft, and works through a complete example: choosing a motor, pump and electric motor for a drive that needs 1,200 N·m at 150 rpm.
Displacement: the number that defines a hydraulic motor
Every hydraulic motor is described first by its displacement, Vg: the volume of oil needed to turn the shaft through one revolution, given in cm³/rev (or in³/rev). Displacement links the hydraulic side to the mechanical side in two ways:
- Pressure × displacement gives torque. A bigger motor produces more torque from the same pressure.
- Flow ÷ displacement gives speed. A bigger motor turns more slowly on the same flow.
So a large-displacement motor is a high-torque, low-speed machine, and a small one is a low-torque, high-speed machine. The power, which is torque times speed, is set by the flow and pressure, not by the motor size. This is the same trade-off as a cylinder, where bore area turns pressure into force and flow into speed; our guide to hydraulic cylinder force, speed and power covers the linear case.
Hydraulic motor torque calculation
In one revolution the oil does work equal to pressure drop times volume, Δp × Vg, and the shaft does work equal to torque times 2π. Setting the two equal gives the theoretical torque:
Tth = Vg × Δp / (2π)
With Vg in cm³/rev and Δp in bar (1 bar = 10⁵ Pa, 1 cm³ = 10⁻⁶ m³), the units collapse into a convenient working formula:
T (N·m) = Vg (cm³/rev) × Δp (bar) × ηhm / (20π) = 0.0159 × Vg × Δp × ηhm
- T = output torque at the shaft, N·m
- Vg = motor displacement, cm³/rev
- Δp = pressure drop across the motor, bar
- ηhm = hydraulic-mechanical efficiency (friction and internal pressure losses), typically about 0.90 for a good motor near rated conditions
Example: a 100 cm³/rev motor with a 150 bar pressure drop gives a theoretical 0.0159 × 100 × 150 = 238.7 N·m. With ηhm = 0.90 the shaft delivers about 215 N·m.
Turned around, the formula sizes the motor for a known load torque:
Vg = 20π × T / (Δp × ηhm)
Hydraulic motor speed from flow
If no oil leaked, the shaft would turn once for every Vg of oil supplied. Real motors leak a little oil past their gears, vanes or pistons into the case or the return, so not all of the flow makes the shaft turn. The volumetric efficiency ηv accounts for this:
n (rpm) = 1000 × Q (L/min) × ηv / Vg (cm³/rev)
and the flow needed for a given speed is:
Q (L/min) = Vg × n / (1000 × ηv)
Example: the same 100 cm³/rev motor fed with 40 L/min at ηv = 0.93 turns at 1000 × 40 × 0.93 / 100 = 372 rpm. Leakage rises with pressure and with thinner (hotter) oil, so a motor slows down a little as the load increases. If the speed must stay constant under load, the circuit needs a pressure-compensated flow control or a closed-loop drive.
Power and efficiency
The hydraulic power going into the motor and the mechanical power coming out are:
Pin (kW) = Q (L/min) × Δp (bar) / 600
Pout (kW) = T (N·m) × n (rpm) / 9,549
The ratio is the overall efficiency, which is the product of the two partial efficiencies:
ηt = Pout / Pin = ηv × ηhm
Manufacturer data for piston motors typically gives ηhm of about 0.90 to 0.95 and overall efficiencies of about 0.80 to 0.90 near rated conditions. Gear and orbital (gerotor) motors are usually somewhat lower, and every type loses efficiency at low pressure and at very low speed. Use the curves from the catalogue of the motor you are considering whenever you can; the values in this guide are planning figures.
Use the pressure drop, not the gauge pressure
The torque formula uses Δp, the difference between the inlet pressure p₁ and the outlet pressure p₂. A motor whose outlet sees 10 bar of return-line back pressure, from a filter, a cooler or a valve, loses that 10 bar from its torque. In a closed-loop (hydrostatic) drive the low-pressure side is held at the charge pressure, typically in the region of 20 bar, and that too must be subtracted. When you size a motor, decide the maximum working pressure at the pump, subtract the losses in hoses and valves on the way to the motor, then subtract the back pressure on the outlet. What remains is the Δp available for torque.
Worked example: a 1,200 N·m drive at 150 rpm
A conveyor head drive needs 1,200 N·m at 150 rpm at the drive shaft. A low-speed, high-torque motor will be coupled directly to the shaft. The power unit has a maximum working pressure of 210 bar, the back pressure in the return line is 10 bar and about 10 bar is lost in the valve and hoses. Planning efficiencies: ηhm = 0.90, ηv = 0.93 for the motor, and an overall efficiency of 0.85 for the pump.
Step 1: available pressure drop and required displacement
Δp = 210 − 10 (losses) − 10 (back pressure) = 190 bar.
Vg = 20π × 1,200 / (190 × 0.90) = 75,398 / 171 = 440.9 cm³/rev
Choose the next catalogue size up, here 470 cm³/rev.
Step 2: working pressure with the chosen motor
Δp = 20π × 1,200 / (470 × 0.90) = 178.2 bar, so the motor inlet pressure is about 178.2 + 10 = 188 bar and the pump has to deliver about 198 bar. At the full 190 bar drop the motor could produce 470 × 190 × 0.90 / (20π) = 1,279 N·m, a margin of about 7% for starting and overloads.
Step 3: flow for 150 rpm
Q = 470 × 150 / (1000 × 0.93) = 75.8 L/min
Step 4: power at the motor
- Shaft power: Pout = 1,200 × 150 / 9,549 = 18.85 kW
- Hydraulic power in: Pin = 75.8 × 178.2 / 600 = 22.5 kW
- Check: 18.85 / (0.93 × 0.90) = 22.5 kW, an overall motor efficiency of 0.84
Step 5: pump and electric motor
With a 1,450 rpm electric motor and a pump volumetric efficiency of 0.95, the pump displacement is 75.8 × 1,000 / (1,450 × 0.95) = 55.0 cm³/rev. A 56 cm³/rev pump gives about 77.1 L/min, which turns the hydraulic motor at about 153 rpm.
Electric motor power: P = Q × p / (600 × ηpump) = 75.8 × 198 / (600 × 0.85) = 29.5 kW, so a 30 kW motor is the natural choice. For this step, our guide to choosing a motor and gearbox from power and speed and the motor and drive calculator help with standard motor sizes and service factors.
Quantity | Result |
|---|---|
Required displacement | 440.9 cm³/rev → 470 cm³/rev chosen |
Pressure drop at 1,200 N·m | 178.2 bar (inlet ≈ 188 bar) |
Maximum torque at 190 bar drop | 1,279 N·m |
Flow for 150 rpm | 75.8 L/min |
Motor shaft power / hydraulic input | 18.85 kW / 22.5 kW |
Pump displacement at 1,450 rpm | 55.0 cm³/rev → 56 cm³/rev |
Electric motor | 29.5 kW → 30 kW |
The chain from electric motor to shaft loses about 36% of the power: 29.5 kW into the pump becomes 18.9 kW at the conveyor shaft. That loss turns into heat in the oil, which is why hydraulic power units with continuous duty usually need an oil cooler; its capacity is often estimated at around a quarter to a third of the installed power.
Direct drive or a fast motor with a gearbox?
The same drive could use a small, fast motor and a reduction gearbox. With a 5:1 gearbox at 96% efficiency, the motor has to supply 1,200 / (5 × 0.96) = 250 N·m at 750 rpm. Assuming a piston motor with ηhm = 0.92 at the same 190 bar drop:
Vg = 20π × 250 / (190 × 0.92) = 89.9 cm³/rev → a 90 cm³/rev motor, needing 90 × 750 / (1000 × 0.95) = 71.1 L/min.
The flow is almost the same as for the direct drive, because the power is the same. The choice is about cost, space, efficiency at low speed and how smoothly the drive must run when creeping. Low-speed, high-torque motors avoid the gearbox and give a compact, sealed drive; a fast piston motor and gearbox is usually more efficient and copes better with long continuous duty. The gearbox calculations are in the gear ratio calculator.
Checking the result in imperial units
In US units the formulas become:
- Torque: T (lbf·in) = D (in³/rev) × Δp (psi) × ηhm / (2π)
- Speed: n (rpm) = 231 × GPM × ηv / D
- Hydraulic power: HP = GPM × psi / 1,714
For the example, 470 cm³/rev = 28.68 in³/rev and 178.2 bar = 2,585 psi. Torque = 28.68 × 2,585 × 0.90 / (2π) = 10,620 lbf·in = 885 lbf·ft, which is 1,200 N·m. The flow is 75.8 / 3.785 = 20.0 GPM, and 20.0 × 2,585 / 1,714 = 30.2 hp = 22.5 kW, matching the metric answer. The unit converter handles bar, psi, cm³ and in³ if you are mixing catalogues.
Practical checks before you order
- Starting torque. Friction is higher at standstill, so a motor delivers less torque when breaking away than when running. Catalogues list starting torque or starting efficiency separately; check it against the breakaway torque of the load, which for a loaded conveyor or a winch can be well above the running torque.
- Speed range. Every motor has a minimum speed for smooth running and a maximum speed and flow. Very slow speeds can make some motor types run unevenly.
- Peak and continuous pressure. Catalogues give a continuous rating and an intermittent or peak rating. Size on the continuous value and set the relief valve so the peak value is never exceeded.
- Back pressure and case drain. Many motors limit the pressure allowed in the case. A motor with an external drain line must have it piped directly to the tank.
- Holding the load. A hydraulic motor leaks, so it cannot hold a suspended load on its own. Winches and hoists need a mechanical brake and a counterbalance or overcentre valve.
- Radial and axial shaft loads. A sprocket, pulley or pinion mounted on the motor shaft puts a side load on its bearings; check it against the motor's allowed shaft load curve.
Quick reference
To find | Formula (metric) |
|---|---|
Torque | T = Vg × Δp × ηhm / (20π) N·m |
Displacement for a torque | Vg = 20π × T / (Δp × ηhm) cm³/rev |
Speed | n = 1000 × Q × ηv / Vg rpm |
Flow for a speed | Q = Vg × n / (1000 × ηv) L/min |
Hydraulic power | P = Q × Δp / 600 kW |
Shaft power | P = T × n / 9,549 kW |
Overall efficiency | ηt = ηv × ηhm |
For the cylinder side of the same circuit, the hydraulic cylinder calculator works out force, speed and flow from bore, rod and pressure. Treat the efficiencies used here as starting values, and confirm the final motor against the manufacturer's performance data for torque, speed, pressure and shaft loads.