Skip to content
Guides

Hydraulic cylinder force, speed and power

How to work out the push and pull force of a hydraulic cylinder from bore, rod and pressure, then its speed from pump flow and the motor power it needs.

By Site AdministratorUpdated 5 min read

A hydraulic cylinder is simple to size on paper, yet quotations still go wrong because the push and pull sides are treated as equal, the pump flow is guessed, or bar is mixed with MPa. Three numbers decide almost everything: the bore, the rod diameter and the working pressure. Add the pump flow and you also get the speed, the cycle time and the power the motor has to supply.

The three formulas you need

Every figure below follows from force = pressure × area. With pressure in bar and area in cm², the units work out neatly because 1 bar = 10 N/cm².

Piston and annulus area

  • Piston (bore) area A₁ (cm²) = π × D² ÷ 4, with the bore D in cm.
  • Rod area (cm²) = π × d² ÷ 4, with the rod diameter d in cm.
  • Annulus area A₂ (cm²) = A₁ − rod area. This is the ring of piston face left on the rod side.
  • Area ratio φ = A₁ ÷ A₂. It tells you how much slower and stronger the extend stroke is than the retract stroke.

Force

  • Push (extend) force F (kN) = p (bar) × A₁ (cm²) ÷ 100.
  • Pull (retract) force F (kN) = p (bar) × A₂ (cm²) ÷ 100.
  • To express it as a load in tonnes, divide kN by 9.80665.

Speed and power

  • Speed v (m/s) = Q (L/min) ÷ (6 × A), using A₁ for extend and A₂ for retract.
  • Hydraulic power P (kW) = p (bar) × Q (L/min) ÷ 600. This is the power in the oil; the electric motor must also cover pump losses, so divide by the pump's overall efficiency.

A worked example

Take a cylinder with a 100 mm bore, a 56 mm rod and a 500 mm stroke, worked at 160 bar (16 MPa, about 2,320 psi) and fed by a pump delivering 40 L/min.

  • Piston area A₁ = π × 10² ÷ 4 = 78.54 cm².
  • Rod area = π × 5.6² ÷ 4 = 24.63 cm², so the annulus A₂ = 78.54 − 24.63 = 53.91 cm².
  • Area ratio φ = 78.54 ÷ 53.91 = 1.46.
  • Push force = 160 × 78.54 ÷ 100 = 125.7 kN, which is 12.8 t.
  • Pull force = 160 × 53.91 ÷ 100 = 86.3 kN, which is 8.8 t.
  • Extend speed = 40 ÷ (6 × 78.54) = 0.085 m/s (85 mm/s), so the 500 mm stroke takes 5.9 s.
  • Retract speed = 40 ÷ (6 × 53.91) = 0.124 m/s (124 mm/s), so the return takes 4.0 s and a full cycle about 9.9 s before valve and dwell time.
  • Hydraulic power = 160 × 40 ÷ 600 = 10.7 kW. With an overall pump efficiency of 85%, the motor has to deliver 10.7 ÷ 0.85 = 12.6 kW, so the next standard IEC size is 15 kW.

Two more numbers from the same cylinder are easy to overlook. A full extend fills the bore side with 78.54 × 50 = 3,927 cm³ (3.9 L) of oil, while the rod side holds only 2.7 L, so the tank level moves by the 1.2 L the rod displaces. And when the cylinder retracts at 40 L/min into the rod side, the bore side pushes out 40 × 1.46 = 58 L/min. The return line, filter and valve must be sized for that larger flow, not for the pump flow.

Working backwards: choosing the bore

Usually the load is known and the bore is the unknown. Rearrange the force formula: A₁ = F × 100 ÷ p, then D = √(4 × A₁ ÷ π).

Suppose a press needs 200 kN at 160 bar. The area required is 200 × 100 ÷ 160 = 125 cm², so D = √(4 × 125 ÷ π) = 12.6 cm. A 125 mm bore gives 122.7 cm² and only 196 kN, which is just short, so either raise the pressure to 163 bar or step up to a 140 mm bore. At 160 bar a 140 mm bore gives 153.9 cm² and 246 kN, which leaves room for friction and a margin. A larger bore costs speed, though: at the same 40 L/min it extends at 43 mm/s instead of 85 mm/s, so the pump may need to grow as well.

Reading the result

The formulas give the theoretical force at the cylinder. Seal friction, back pressure in the return line and pressure lost in hoses and valves all take something away, so many designers allow a few percent for friction and keep the working load well below the theoretical figure. Speed is directly proportional to flow and inversely proportional to area, so a bigger bore with the same pump is stronger but slower. Power is set by pressure and flow together, which is why a fast, high-force cylinder needs a large motor even though the cylinder itself looks small.

What these formulas leave out

  • They do not check the rod for buckling. A long, slender rod pushing a heavy load can bend well before the force limit is reached, so a long-stroke cylinder needs a separate buckling check using its mounting style.
  • They do not check the tube wall, end caps or mounting for the pressure; that is a strength calculation for the cylinder maker.
  • They assume the pump delivers its rated flow at full pressure. Pump volumetric efficiency, relief valve setting and leakage all reduce the real speed.
  • They ignore the time to accelerate the load and the time valves take to shift, so a real cycle is longer than the stroke time.
  • They give no prices; they are a sizing check only.

Common mistakes

  • Using the full bore area for the pull force. The rod side is always weaker.
  • Mixing units: entering MPa as bar (a factor of 10) or mm² as cm² (a factor of 100).
  • Sizing the return line for the pump flow, when the bore side returns about 1.5 times as much on retraction.
  • Choosing the motor from hydraulic power alone, with no allowance for pump efficiency.
  • Taking the relief valve setting as the working pressure and leaving no margin for the load to vary.

To change bar to psi or MPa, or kN to tonnes-force, use the engineering unit converter. For the electric motor that drives the pump, the motor power and gearbox calculator gives the standard frame and torque. To check the hydraulic lines carry the flow at a sensible velocity, try the pipe pressure drop and velocity calculator, and for more unit traps read converting engineering units without mistakes.