Tank heating time with a steam coil: heat, area and steam
How long a steam coil takes to heat a tank, and how big the coil must be: heat required, the batch heating formula, U values, coil area and steam load, worked through for a 10 m³ water tank.
A tank that takes three hours to heat when the process needs it in one holds up a whole shift. A coil that is far bigger than needed costs money, crowds the tank and makes control harder. Both mistakes come from the same place: a heating calculation that skipped a step. A proper tank heating time calculation needs only a handful of numbers, the mass in the tank, the temperatures, the steam pressure and a realistic heat transfer coefficient, and it answers three questions at once: how much heat, how much coil area and how much steam. This guide works through all three, with a complete example for a 10 m³ water tank heated by a submerged steam coil.
Step 1: the heat the batch needs
The energy needed to warm a liquid is the familiar sensible heat formula:
Q = m × cp × (T2 − T1)
- Q = heat required, kJ
- m = mass of liquid in the tank, kg
- cp = specific heat capacity, kJ/kg·K (4.19 for water; roughly 1.8 to 2.2 for most oils)
- T1, T2 = starting and final temperatures, °C
Use the mass, not the volume. Water is close to 1 kg per litre, but oils, syrups and solutions are not, so multiply the working volume by the density first. Our tank capacity calculator gives the volume of a cylindrical tank from its diameter and height. If the tank wall, an agitator or a jacket is heavy compared with the contents, add their mass times the specific heat of steel (about 0.5 kJ/kg·K) as well.
Dividing Q by the heating time gives the average heat duty in kW. That average is useful for a first look, but it hides an important fact: a steam coil does not deliver heat at a steady rate.
Step 2: why the heating rate falls as the tank warms
Steam condenses inside the coil at the saturation temperature for its pressure, Ts. The heat flowing through the coil wall is proportional to the difference between Ts and the liquid temperature. At the start the liquid is cold and the difference is large; as the tank warms, the difference shrinks and so does the heat flow. The result is that the tank temperature climbs along a curve that slowly flattens out towards Ts.
For a well-mixed tank and a constant steam temperature, an energy balance gives the classic batch heating equation:
t = (m × cp / (U × A)) × ln[(Ts − T1) / (Ts − T2)]
- t = heating time, s
- U = overall heat transfer coefficient of the coil, W/m²·K
- A = outside surface area of the coil, m²
- Ts = steam saturation temperature in the coil, °C
- m × cp in J/K (kg × J/kg·K)
Rearranged, the same equation gives the coil you need for a target time:
U × A = m × cp × ln[(Ts − T1) / (Ts − T2)] / t
The term (T2 − T1) / ln[(Ts − T1) / (Ts − T2)] is the log mean temperature difference for the batch. Using a simple arithmetic mean instead gives a slightly smaller, optimistic coil area; the logarithmic form is the safer one. The same idea is used for continuous exchangers in our heat exchanger area calculator.
Step 3: choosing a realistic U value
U is the number that makes or breaks the result, and it is the one most often guessed. For steam coils submerged in water, Spirax Sarco publishes typical ranges that rise with the mean temperature difference between steam and water:
- around 30 °C difference: 550 to 1,300 W/m²·K
- around 60 °C difference: 1,000 to 1,700 W/m²·K
- around 110 °C difference: 1,300 to 2,700 W/m²·K
For design, the same source recommends about 550 W/m²·K for low-pressure steam (below 2 bar g) with natural circulation and about 1,100 W/m²·K at higher pressure or with assisted circulation, and its own worked example uses 650 W/m²·K for a stainless steel coil. In practice, pick the lower end unless the tank is stirred: scale, sludge on the coil and air or condensate left inside the coil all reduce U, and a coil that is slightly too big is easily controlled while one that is too small can never catch up. Oils and viscous liquids give much lower values, often only 50 to 300 W/m²·K, so do not use water figures for them. Many designers also add about 10% to the calculated area as a fouling allowance.
Step 4: steam consumption and the peak load
When steam condenses it gives up its latent heat, hfg, so the total steam used for the batch is:
ms = Q / hfg
The rate of steam use, though, follows the heat flow, which is highest at the start:
ṁs = U × A × (Ts − T) / hfg
The control valve, the steam supply line and the steam trap must be sized for the start-up load, not the average. Sizing them on the average is a classic reason why a tank heats more slowly than the calculation promised. Our steam pipe sizing guide shows how to size the line for that peak flow, and the steam and boiler calculator turns the steam demand into boiler duty and fuel.
Worked example: heating a 10 m³ water tank in two hours
A process tank holds 10 m³ of water, about 10,000 kg. It must be heated from 15 °C to 65 °C in 2 hours (7,200 s) with a stainless steel steam coil. Steam is supplied at 3 bar g; allowing for the drop across the control valve, the coil is designed for 2 bar g (3 bar a), where Ts = 133.5 °C and hfg = 2,163 kJ/kg. The tank is not agitated, so U = 600 W/m²·K is taken as a cautious design value.
1. Heat required
- Q = 10,000 × 4.19 × (65 − 15) = 2,095,000 kJ, about 582 kWh
- Average duty: 2,095,000 / 7,200 = 291 kW
- Imperial check: 22,046 lb × 1 Btu/lb·°F × 90 °F = 1,984,000 Btu, which is the same 2.09 GJ
2. Coil area
- ln[(133.5 − 15) / (133.5 − 65)] = ln(118.5 / 68.5) = 0.548
- U × A = 41,900,000 J/K × 0.548 / 7,200 s = 3,189 W/K
- A = 3,189 / 600 = 5.3 m²; with 10% for fouling, 5.85 m²
- The log mean temperature difference is 50 / 0.548 = 91.2 K. The arithmetic mean (133.5 − 40 = 93.5 K) would have given 5.19 m², about 2% less.
A DN32 pipe (42.4 mm outside diameter) has 0.133 m² of outside surface per metre, so about 45 m of DN32 pipe gives 6 m², arranged as a serpentine or spiral close to the tank bottom. With 6 m² installed, the same equation predicts a heating time of about 1.77 hours, which leaves some margin for fouling.
3. Steam consumption
- Total steam for the batch: 2,095,000 / 2,163 = 968 kg
- Average rate: 968 / 2 = 484 kg/h
- At the start (water at 15 °C): 3,189 × 118.5 = 378 kW, or 629 kg/h
- At the end (water at 65 °C): 3,189 × 68.5 = 218 kW, or 364 kg/h
The peak steam flow is 30% higher than the average. The control valve, supply line and trap should therefore be sized for at least 630 kg/h, plus the losses below.
4. Heat losses
An uninsulated steel tank loses heat from its walls and lid. As a rough guide, a bare surface loses about 10 W/m²·K to still indoor air through convection and radiation together. With 25 m² of surface at 65 °C in a 20 °C room, that is about 10 × 25 × 45 = 11 kW, or about 19 kg/h of steam just to hold temperature, every hour the tank stays hot. With 50 mm of mineral wool it drops to roughly 1 kW. Use the insulation and heat loss calculator for your own tank, and add the loss to the heating duty: for a bare tank heated slowly, it can add several percent to the heating time.
Result
Install about 6 m² of coil (45 m of DN32 stainless pipe), size the steam valve, line and trap for about 650 kg/h at the start-up condition, and expect close to 1 tonne of steam per batch. If the coil already exists, run the equation the other way: a 4 m² coil in the same tank would need 2.66 hours instead of 2.
Direct steam injection: a quick comparison
If steam is blown straight into the water instead of through a coil, the steam gives up its total heat, not just its latent heat, and the condensate stays in the tank. For the same batch, the steam needed is Q divided by the steam enthalpy (2,725 kJ/kg at 3 bar a) minus the enthalpy of water at 65 °C (272 kJ/kg): 2,095,000 / 2,453 = 854 kg. That is about 12% less steam than the coil, and heating is much faster, but the tank gains about 854 kg of water and the steam must be clean enough to come into contact with the product. Injection also needs a proper sparger or injector to avoid noise and hammer.
Common mistakes in tank heating calculations
- Using the supply pressure in the coil. The control valve drops the pressure, and with it Ts. Use the coil pressure, not the boiler pressure.
- Optimistic U values. Values for agitated tanks or clean test conditions are not valid for a still, scaled tank.
- Sizing the valve and trap on the average load. The start-up load is the highest; undersized valves and traps waterlog the coil and slow the heating.
- Poor condensate drainage. A coil must fall towards its outlet and drain freely. Near the end of heating, the steam pressure in a temperature-controlled coil can fall to or below the condensate back pressure, the coil stalls and fills with water, and U collapses.
- Forgetting the vessel and losses. Heavy steel, a cold lid or an open top can add noticeably to the heat needed.
- Heating too close to the steam temperature. The last few degrees before Ts take the longest. If T2 is close to Ts, raise the steam pressure rather than adding endless coil area.
Quick reference: the formulas
- Heat required: Q = m × cp × (T2 − T1)
- Heating time: t = (m × cp / (U × A)) × ln[(Ts − T1) / (Ts − T2)]
- Coil area: A = m × cp × ln[(Ts − T1) / (Ts − T2)] / (U × t)
- Steam per batch: ms = Q / hfg; instantaneous rate: ṁs = U × A × (Ts − T) / hfg
- Typical U, steam coil in water: about 550 to 1,700 W/m²·K, depending on pressure, temperature difference and circulation
For the theory behind the temperature term, see the Wikipedia article on the logarithmic mean temperature difference. Get the mass and the U value honest, size the steam side for the start-up load, and the tank will be hot when the process needs it.