Skip to content
Guides

V-belt drives: pulley ratio, belt length and centre distance

How to size a V-belt drive: driven pulley from the speed ratio, belt speed, belt length and centre distance, arc of contact and number of belts, with a worked example.

By Site AdministratorUpdated 6 min read

A V-belt drive looks like the simplest part of a machine: two pulleys, a few belts, a motor on slide rails. Yet the same mistakes turn up again and again on site and in quotations. The driven shaft runs at the wrong speed because the pulley ratio was worked from outside diameters, the belt ordered is a size too short, or the drive slips because the small pulley has too little belt wrapped around it. All of it can be checked on one page with a handful of formulas, and this guide walks through them with a worked example.

The formulas you need

Every calculation below uses the pitch (datum) diameter of each pulley, not its outside diameter. The pitch line is where the belt actually carries its load, roughly at the belt's neutral layer inside the groove. Belt catalogues list pulleys by their datum diameter for exactly this reason.

Speed ratio

  • Speed ratio i = D ÷ d = n₁ ÷ n₂, where d is the small (driving) pulley, D the large (driven) pulley, n₁ the motor speed and n₂ the driven speed, both in rpm.
  • Driven speed n₂ = n₁ × d ÷ D.
  • Pulley needed for a target speed D = d × n₁ ÷ n₂.
  • Belts creep slightly as they stretch and relax around each pulley, typically about 1–2% in a well-tensioned drive, so the real driven speed is a little below the calculated one.

Belt speed

  • Belt speed v (m/s) = π × d (mm) × n₁ (rpm) ÷ 60,000.
  • Each belt profile has a maximum speed set by the manufacturer, because centrifugal force lifts the belt out of the groove and the pulleys themselves have a safe rim speed. Very low belt speeds are also a warning sign: at the same power, half the speed means twice the belt pull.

Belt length and centre distance

  • Pitch length of an open belt L = 2C + π(D + d) ÷ 2 + (D − d)² ÷ (4C), with C the centre distance and everything in mm.
  • Centre distance for a chosen belt: first work out b = 2L − π(D + d), then C = [b + √(b² − 8(D − d)²)] ÷ 8.
  • A common starting range for a new drive is 0.7(D + d) ≤ C ≤ 2(D + d). Shorter centres reduce the wrap on the small pulley; much longer ones let the belt whip.

Arc of contact, torque and belt pull

  • Arc of contact on the small pulley θ = 180° − 2 × asin[(D − d) ÷ (2C)]. A quick approximation is θ ≈ 180° − 57.3 × (D − d) ÷ C.
  • Shaft torque T (N·m) = 9,550 × P (kW) ÷ n (rpm).
  • Effective belt pull Fe (N) = 1,000 × P (kW) ÷ v (m/s). This is the difference between the tight-side and slack-side tension that actually moves the load.

A worked example

A 7.5 kW, 4-pole motor running at 1,450 rpm has to drive a fan at about 725 rpm. The motor carries a 125 mm datum diameter pulley.

  • Ratio needed: i = 1,450 ÷ 725 = 2.0, so the fan pulley is D = 125 × 2.0 = 250 mm.
  • Belt speed: v = π × 125 × 1,450 ÷ 60,000 = 9.49 m/s, comfortably inside the usual range for V-belts.
  • Trial centre distance: the range is 0.7 × 375 = 263 mm to 2 × 375 = 750 mm, so take C = 400 mm.
  • Belt length: L = 2 × 400 + π × 375 ÷ 2 + 125² ÷ (4 × 400) = 800 + 589.0 + 9.8 = 1,398.8 mm.
  • Suppose the nearest belt your supplier stocks has a 1,400 mm pitch length. Then b = 2 × 1,400 − π × 375 = 1,621.9 mm, and C = [1,621.9 + √(1,621.9² − 8 × 125²)] ÷ 8 = [1,621.9 + 1,582.9] ÷ 8 = 400.6 mm. The motor sits 0.6 mm further back than the trial position, well within the travel of the slide rails.
  • Arc of contact: θ = 180° − 2 × asin(125 ÷ 801.2) = 180° − 2 × 9.0° = 162°. That is a healthy wrap; below about 120° grip falls off noticeably.
  • Motor torque: T = 9,550 × 7.5 ÷ 1,450 = 49.4 N·m. At the fan shaft, the torque doubles with the ratio to 98.8 N·m before belt losses.
  • Effective belt pull: Fe = 1,000 × 7.5 ÷ 9.49 = 790 N, shared between the belts in the set.
  • Real fan speed: with 1.5% creep the fan turns at about 725 × 0.985 = 714 rpm. If the fan curve needs the full 725 rpm, a 245 mm pulley would bring it back, if one is available.

How many belts?

The number of belts comes from the manufacturer's power rating, not from a formula you can derive on paper. The method is the same in every catalogue:

  1. Multiply the motor power by a service factor for the driven machine and the hours it runs. A fan running steadily needs a lower factor than a crusher or a reciprocating compressor. The result is the design power.
  2. Read the rated power per belt from the table for your belt profile, small-pulley diameter and motor speed.
  3. Correct that rating for the arc of contact and the belt length, using the catalogue's correction factors.
  4. Number of belts = design power ÷ corrected power per belt, always rounded up.

Take the example drive and assume a service factor of 1.2: design power is 7.5 × 1.2 = 9.0 kW. If, purely to show the arithmetic, the corrected rating were 3.2 kW per belt, you would need 9.0 ÷ 3.2 = 2.8, so three belts. Use the figures from the catalogue of the belt you are actually buying, because ratings differ between profiles and makers.

Checks before you order

  • Small pulley not too small. Every profile has a minimum recommended pulley diameter. Going below it bends the belt too hard and shortens its life, even when the power rating looks adequate.
  • Bearing and shaft load. A tensioned set of belts pulls the motor and machine shafts towards each other with a force well above the effective pull. Long overhangs on small motor shafts are a common cause of bearing failure.
  • Units. Mixed horsepower, kW, inch and millimetre data are the usual source of a wrong ratio. Convert everything first.
  • Matched sets. On multi-belt drives, replace all belts together so they share the load.
  • Efficiency. A well-maintained V-belt drive is commonly quoted at roughly 93–97% efficiency; a slipping, under-tensioned one is much worse and runs hot.

Calculators that help

To pick the motor size and gearbox ratio before you design the belt stage, use the motor and gearbox selection calculator. To switch between kW and HP, N·m and lbf·ft, or rpm and rad/s, the engineering unit converter does it in one step. If the belt drive powers a conveyor, the belt conveyor capacity and power calculator gives the shaft power to start from, and the guide to belt conveyor capacity and drive power explains the figures behind it.

Summary

Work from pitch diameters, size the driven pulley from the speed ratio, check the belt speed, calculate the belt length from a trial centre distance, then recalculate the centre distance for the belt you can actually buy. Confirm the arc of contact and finish with the catalogue's power rating to set the number of belts. Done in that order, a V-belt drive runs at the speed you planned and the belts last.

#v-belt#pulley#speed ratio#power transmission#belt drive