Skip to content

Runs in your browser

Belt conveyor capacity & power

Enter the belt, the speed and what it is carrying. The calculator returns the capacity in tonnes an hour, the load the idlers see, and the drive power needed for the length and the lift.

How this works →

Your figures

Standard widths: 500, 650, 800, 1000, 1200, 1400.

1.0–2.0 for grain and meal, up to 3.5 for ore. Fast belts spill and wear.

Wheat 780, paddy 580, meal 600, cement 1400, coal 850.

Vertical rise from loading point to discharge. Zero for a horizontal run.

Result

Capacity

Capacity

279.9 m³/h at 750 kg/m³

210 tonnes/hour
Per 8-hour shift
1,680 tonnes
Load cross-section

20° on 800 mm belt

518 cm²
Load per metre

What the idlers carry

38.9 kg/m

Power

Drive power

Friction and lift, with 20% for drive losses and starting

3.49 kW
Motor frame

Next IEC size

4 kW
Horizontal component

Over 30 m

0.62 kW
Lift component

4 m rise

2.29 kW

Belt tension, idler spacing and takeup are a separate calculation — this sizes the drive, not the belt.

Questions

How is capacity worked out?
From the cross-section of material the belt can carry and how fast it moves. Usable width is about ninety percent of the belt, leaving an edge allowance, and the troughing angle decides how much section that width holds. Capacity is that area times speed times bulk density.
What belt speed is sensible?
One to two metres a second for grain, meal and similar free-flowing materials. Faster belts carry more but spill at transfer points, wear the skirting, and degrade fragile products. Up to three and a half is normal for ore and aggregates, which do not care.
Does this size the belt itself?
No. It sizes the drive. Belt tension, ply rating, idler spacing, takeup travel and pulley diameters are a separate calculation that depends on the tensions around the whole circuit, and they are what decide the belt specification.
Why add twenty percent to the power?
Drive train losses, plus the margin needed to start a loaded belt from rest, which takes considerably more than running it. A drive sized exactly on running power will not restart after a power cut with material still on the belt.