How the Belt conveyor calculator turns belt width, speed, bulk density and trough angle into tonnes an hour, then adds friction and lift to size the drive motor.

By Site AdministratorUpdated 3 min read

A conveyor that is too slow starves the plant, and one with an undersized motor trips the first time it starts under load. The Belt conveyor calculator takes the belt width, speed, bulk density, trough angle, centre distance and lift, and returns the capacity in tonnes an hour and the drive power needed.

How the calculation works

Capacity comes from the cross-section of material on the belt, the speed and the density:

  • Usable width (m) = belt width ÷ 1000 × 0.9, which leaves an edge allowance.
  • Load area (m²) = trough factor × usable width². The factor is 0.045 for a flat belt, 0.10 for a 20° trough, 0.13 for 30° and 0.145 for 35°.
  • Volume (m³/h) = area × speed × 3600, and capacity (t/h) = volume × density ÷ 1000.

Power then has two parts, both with g = 9.80665:

  • Load per metre = capacity × 1000 ÷ (speed × 3600), in kg/m.
  • Horizontal power (kW) = 0.022 × (load per metre + 25) × g × speed × centre distance ÷ 1000. The 0.022 is the friction factor and the 25 kg/m stands for the moving belt and idlers.
  • Lift power (kW) = load per metre × g × speed × lift ÷ 1000.
  • Drive power = (horizontal + lift) × 1.2, the 20% covering drive losses and starting. The motor frame is the next IEC size above it.

The starting values are an 800 mm belt at 1.5 m/s, 750 kg/m³ material, a 20° trough, 30 m centres and 4 m of lift.

A worked example

  • Usable width = 0.8 × 0.9 = 0.72 m, so area = 0.10 × 0.72² = 0.0518 m² (518 cm²).
  • Volume = 0.05184 × 1.5 × 3600 = 279.9 m³/h, and capacity = 279.9 × 750 ÷ 1000 = 210.0 t/h, or 1,680 t in an 8-hour shift.
  • Load per metre = 210 000 ÷ 5400 = 38.9 kg/m.
  • Horizontal power = 0.022 × (38.9 + 25) × 9.80665 × 1.5 × 30 ÷ 1000 = 0.62 kW.
  • Lift power = 38.9 × 9.80665 × 1.5 × 4 ÷ 1000 = 2.29 kW.
  • Drive power = (0.62 + 2.29) × 1.2 = 3.49 kW, so the motor frame is 4 kW.

Change only the trough to flat and the factor drops to 0.045: capacity falls to 94.5 t/h and the power to 1.73 kW. The troughing angle alone more than halves the throughput.

Reading the result

Capacity is the rate at which the belt is full to its design section, not an average over a shift. Load per metre is what the idlers carry, so it matters when you choose idler spacing. In the example the lift supplies 2.29 of the 2.91 kW before the 20% allowance, so a few metres of rise cost more than 30 m of flat run. The motor frame row shows the standard size to ask for.

What the tool assumes and leaves out

  • It sizes the drive, not the belt. Belt tension, ply rating, idler spacing, takeup and pulley diameters are a separate calculation.
  • Friction is fixed at 0.022 and the moving mass at 25 kg/m. A dusty, long or badly aligned belt can differ.
  • The trough factors and the 90% usable width are conventional values. Loose or surging material may not fill the section.
  • There are no accessories such as ploughs, trippers or skirt friction, and no inclined-length correction: lift and centre distance are entered separately.
  • The tool gives no prices; this is a sizing tool only.

Common mistakes

  • Entering the belt length instead of the centre distance.
  • Using the density of the wet or packed material rather than loose bulk density.
  • Raising the speed to gain capacity without checking spillage and wear at transfer points.
  • Entering the sloping length as the lift. Lift is the vertical rise only.
  • Choosing a drive on running power alone, with no margin to restart a loaded belt.

Try your own figures in the Belt conveyor capacity and power calculator. For the motor and gearbox that follow, use the motor and gearbox selection calculator.