NPSH and cavitation: checking a pump's suction side
What NPSH available and NPSH required mean, how to calculate NPSHa for an open tank, and how hot liquid, altitude and suction lift push a pump into cavitation.
A pump can have the right flow, the right head and the right motor and still fail within weeks because of what happens on its suction side. If the pressure at the impeller eye falls to the vapour pressure of the liquid, bubbles form and then collapse against the vanes. That is cavitation: a gravelly noise, falling head and pitted impellers. The check that prevents it is NPSH, net positive suction head.
The four terms of NPSH available on a pump's suction side.
NPSH available and NPSH required
There are two figures, and only one of them is yours to calculate.
- NPSH available (NPSHa) belongs to the system: the tank, the liquid, the pipe and where the pump sits. It is the pressure margin above vapour pressure at the pump inlet, expressed in metres of the liquid being pumped.
- NPSH required (NPSHr) belongs to the pump and is read off the maker's curve. It rises with flow. Under the Hydraulic Institute convention it is usually published as NPSH3, the suction head at which the pump's total head has already dropped by 3%, so a pump running exactly at NPSHr is already cavitating a little.
The pump is safe only when NPSHa stays comfortably above NPSHr across the whole range of flows it will run at.
How to calculate NPSH available
For a pump drawing from a tank, in metres of liquid:
NPSHa = (Ps − Pv) ÷ (ρ × g) + z − hf
- Ps is the absolute pressure on the liquid surface, in Pa. For an open tank it is atmospheric pressure: 101,325 Pa at sea level, about 89,900 Pa at 1000 m and about 84,600 Pa at 1500 m.
- Pv is the vapour pressure of the liquid at the pumping temperature, in Pa. For water it is about 2,340 Pa at 20 °C, 7,380 Pa at 40 °C, 19,900 Pa at 60 °C and 47,400 Pa at 80 °C.
- ρ is the density in kg/m³ and g = 9.80665 m/s².
- z is the height of the liquid surface above the pump centreline, in metres: positive for a flooded suction, negative for a suction lift.
- hf is the friction loss in the suction pipe, fittings, foot valve and strainer, in metres.
Use absolute pressures throughout. A gauge reading on a closed vessel needs atmospheric pressure added before it goes into the formula.
A worked example
Water at 20 °C (998.2 kg/m³) is drawn from an open sump at sea level. The pump sits 2 m above the water surface and the suction line loses 0.8 m in friction. The pump curve shows an NPSHr of 3.5 m at the duty flow.
- Pressure term = (101,325 − 2,339) ÷ (998.2 × 9.80665) = 98,986 ÷ 9,789 = 10.11 m.
- NPSHa = 10.11 − 2 − 0.8 = 7.31 m.
- Margin = 7.31 − 3.5 = 3.81 m. The pump is comfortable.
Now heat the water to 80 °C (971.8 kg/m³) and keep everything else the same:
- Pressure term = (101,325 − 47,373) ÷ (971.8 × 9.80665) = 53,952 ÷ 9,530 = 5.66 m.
- NPSHa = 5.66 − 2 − 0.8 = 2.86 m, below the 3.5 m the pump needs. It will cavitate.
Move the pump so the tank level is 1.5 m above its centreline instead of 2 m below it, and NPSHa becomes 5.66 + 1.5 − 0.8 = 6.36 m, a margin of 2.86 m. The original cold-water duty at 1500 m altitude, with the 2 m lift, gives (84,560 − 2,339) ÷ 9,789 − 2.8 = 5.60 m: the altitude alone has taken 1.7 m.
NPSH available in the worked example. Only the hot-water case with a suction lift falls below NPSHr.
What raises NPSH available
- Lower the pump or raise the tank. Every metre of extra flooded head is a metre of NPSHa.
- Shorten the suction line and make it one size larger than the pump branch. Friction rises roughly with the square of velocity, so a bigger pipe gives back far more than it costs. The pipe size and pressure drop calculator gives the friction loss for a given line.
- Remove unnecessary bends, valves and fine strainers from the suction side, and keep the strainer clean.
- Cool the liquid before the pump, or pump it before it is heated, when the process allows.
- Pressurise the suction vessel. A closed tank with a gas blanket adds its pressure to Ps.
Margin and common mistakes
How much margin is enough depends on the pump's speed, size and duty, and the Hydraulic Institute guideline ANSI/HI 9.6.1 covers it in detail. As a starting point, many engineers want at least a metre above NPSHr for small water pumps, and more for hot liquids, high-speed pumps and pumps that run well away from their best efficiency point. Mistakes that turn up again and again:
- Checking NPSH at the design flow only. NPSHr rises with flow, so check the highest flow the pump may run at, such as when a discharge valve is wide open.
- Taking vapour pressure at the normal temperature when the liquid can get hotter in summer or at start-up.
- Forgetting altitude. A site in the hills has less atmosphere pushing liquid into the pump.
- Mixing gauge and absolute pressures, or kPa, bar and metres. The engineering unit converter helps keep the units straight.
- Ignoring a partly blocked foot valve or strainer, which adds to the suction loss a little more every week.
NPSH tells you whether the pump can draw the liquid in; the rest of the selection is covered in how a centrifugal pump works and what its curve tells you. Once the suction side is right, size the drive with the pump head and power calculator, and confirm the final NPSHr against the manufacturer's curve.