Filter press plates and feed pump from slurry volume
How the Filter press and pumps tool turns slurry volume, solids content, plate size and fill time into a plate count, filtration area, feed pump duty and pipe bore.
A chamber filter press holds the cake from one batch, so the plate count follows from how much solid is in the slurry. The Filter press and pumps tool takes the slurry volume, solids content, plate size, chamber depth and fill time, and lists the plates, cloths, frame, pumps, tanks and pipe that follow. You then enter your own rate against each line.
How the calculation works
The starting values are 10 m³ of slurry per batch, 8% solids by volume, an 800 mm plate, a 30 mm chamber and a 0.5 hour fill. The plate size is rounded up to a stock size (470, 630, 800, 1000, 1200 or 1500 mm). Then:
- Cake volume = slurry × solids % × 1.4. The 1.4 is a working bulking factor, because pressed cake holds moisture between the particles.
- Chamber volume = side² × depth × 0.85, with the side in metres. The 0.85 allows for the feed eye and drainage ports taking up the corners.
- Chambers = cake volume ÷ chamber volume, rounded up, never less than 1. Plates = chambers + 1, because a chamber sits between two plates.
- Filtration area = chambers × 2 × side² × 0.85, since both faces of each chamber filter.
- Feed flow (m³/h) = slurry ÷ fill time. Filtrate = slurry minus cake volume.
- Cloths = 2 per plate. The slurry tank is 1.5 batches and the filtrate tank is 1.5 times the filtrate, each rounded up to a stock size. The pipe bore is sized for the feed flow at 1.5 m/s.
The tool also lists two air diaphragm feed pumps at 7 bar (duty and standby), a cake wash pump at half the feed rate, a filtrate transfer pump at the feed rate, a compressor, a hydraulic power pack and a drip tray.
A worked example
Take the starting values: 10 m³, 8%, an 800 mm plate, 30 mm and 0.5 hour.
- Cake = 10 × 0.08 × 1.4 = 1.12 m³.
- Chamber = 0.8 × 0.8 × 0.03 × 0.85 = 0.01632 m³, which is 16.3 litres.
- Chambers = 1.12 ÷ 0.01632 = 68.6, rounded up to 69, so 70 plates and 140 cloths.
- Filtration area = 69 × 2 × 0.64 × 0.85 = 75.1 m².
- Feed flow = 10 ÷ 0.5 = 20 m³/h. Filtrate = 10 − 1.12 = 8.88 m³. The pipe needs a 68.7 mm bore, so NB 80 mm.
- The slurry tank is 10 × 1.5 = 15 m³ and the filtrate tank is 8.88 × 1.5 = 13.3 m³, shown as 15 m³. The wash pump is 10 m³/h.
Change the plate to 1000 mm and the chamber holds 25.5 litres, so 1.12 ÷ 0.0255 = 43.9 rounds up to 44 chambers and 45 plates, with 74.8 m² of area. Lengthen the fill to 1 hour and the feed flow halves to 10 m³/h, which needs a 48.6 mm bore, so NB 50 mm.
Reading the result
Solids content and chamber size set the plate count; fill time sets only the pumps and the pipe. Doubling the solids doubles the plates, but doubling the fill time halves the pump. A bigger plate cuts the plate count roughly with its area, though the cost per plate rises. The basis column shows the arithmetic, for example the cake volume divided by litres per chamber plus one, so you can see where a size comes from before you price it.
What the tool assumes and leaves out
- It prices nothing. You supply the rate for each line and no market prices are built in.
- The whole batch is assumed to be filtered in one press load. If the plate count is larger than a press you would buy, split the batch and enter a smaller volume.
- Filtration area is geometry, not performance. The tool does not model cake resistance, filtration pressure, cycle time, wash time or throughput, and it cannot replace a filterability test.
- The bulking factor of 1.4, the 0.85 chamber allowance and the 1.5 m/s pipe velocity are fixed. A cake that holds more water needs more chambers than shown.
- The pipe is a 60 m allowance with 12 ball valves, not a route.
- Cake handling, flocculant dosing, thickeners, civil work and electrical supply are not in the list.
Common mistakes
- Entering solids by weight when the field is percent by volume.
- Entering the full cycle time as the fill time, which makes the feed pump too small.
- Typing a plate size outside the stock sizes and expecting it to be used as typed. It is rounded up to the next one.
- Reading the filtration area as a throughput figure.
- Forgetting that a 30 mm chamber suits most cakes and a fast-filtering cake may call for 40 mm.
Try your own figures in the Filter press and pumps calculator. To check the motor for the feed pump, use the pump head and power calculator, and for the line, the pipe size and pressure drop calculator.