Agitator power: sizing a mixer motor for a tank

How to estimate agitator power with the power number method, check the impeller Reynolds number and choose the mixer motor and gearbox, with a worked example.

By Site AdministratorUpdated 6 min read

An agitator motor that is too small trips or stalls when the batch thickens; one that is too large wastes money on the motor, gearbox, shaft and seal. For a mixing tank with a standard impeller, the power can be estimated well before you ask a supplier for a quotation, from four numbers: impeller diameter, speed, liquid density and the impeller's power number. This guide shows the formula, how to check that it applies, typical power numbers and a worked example that ends with a motor and gearbox choice.

Diagram of a baffled mixing tank of diameter T and liquid depth H, with a pitched blade impeller of diameter D at clearance C turning at speed N

An agitated tank: impeller of diameter D at clearance C in a tank of diameter T and liquid depth H, with wall baffles.

What sets the power an agitator draws

The impeller pushes liquid, and the power it absorbs depends on how much liquid it moves and how fast. In practice six things matter:

  • Impeller diameter. The strongest effect by far: power rises with the fifth power of diameter.
  • Speed. Power rises with the cube of speed, so a small change in rpm has a large effect.
  • Liquid density. Power is directly proportional to density; a slurry at 1,300 kg/m³ needs 30% more than water.
  • Impeller type. Flat radial blades draw several times more power than pitched blades or hydrofoils of the same diameter.
  • Baffles. Wall baffles stop the liquid swirling round as a solid body. Without them a vortex forms, and the impeller draws less power but mixes poorly.
  • Viscosity. It decides the flow regime, and so whether the power number is constant.

The power number formula

All of this is combined in one dimensionless group, the power number Np. Once you know it for your impeller and tank geometry, the power is:

P = Np × ρ × N³ × D⁵

  • P is the power the impeller delivers to the liquid, in W.
  • Np is the power number of the impeller (dimensionless).
  • ρ is the liquid density, in kg/m³.
  • N is the impeller speed in revolutions per second: rpm ÷ 60.
  • D is the impeller diameter, in m.

The most common slip is putting rpm straight into the formula. Because speed is cubed, that overstates the power by 60³, a factor of 216,000. Use SI units throughout and the answer comes out in watts.

Check the Reynolds number first

The power number is only constant when the flow around the impeller is turbulent. Check this with the impeller Reynolds number:

Re = ρ × N × D² ÷ μ

Here μ is the dynamic viscosity in Pa·s (1 cP = 0.001 Pa·s), and N and D are in the same units as above.

  • Re above about 10,000: turbulent. Np is practically constant and the formula can be used directly. Most water-like liquids in process tanks fall in this range.
  • Re between about 10 and 10,000: transitional. Np changes with Re. Read it from the impeller maker's Np–Re curve at your Reynolds number.
  • Re below about 10: laminar. Np × Re is roughly constant, so power becomes proportional to viscosity × N² × D³ instead. Duties this viscous usually need anchors or helical ribbons, sized from the maker's data.

The exact boundaries differ a little between textbooks, so treat them as a guide rather than sharp limits.

Typical power numbers

These are published turbulent values for impellers in a tank with four standard wall baffles and an impeller about one third of the tank diameter. Rounded values like these are fine for a first estimate; the final figure should come from the impeller supplier for the actual geometry.

  • Six-blade flat disc turbine (Rushton): about 5, with published values from about 4 to 7 depending on baffle width and blade geometry.
  • Six-blade 45° pitched blade turbine: about 1.6.
  • Four-blade 45° pitched blade turbine: about 1.27.
  • Two-blade flat paddle: about 1.8.
  • Three-blade marine propeller: about 0.35.
  • Narrow-blade hydrofoil: about 0.3.

These numbers apply to baffled tanks only. An unbaffled tank draws noticeably less power at the same speed, and its vortex can pull air down to the impeller, so don't use the baffled values for it.

Worked example: a pitched blade agitator

A vertical tank is 2.0 m in diameter and filled to a depth of 2.0 m, holding about 6.28 m³ of liquid. It has four baffles and a four-blade 45° pitched blade turbine of 0.70 m diameter running at 90 rpm. The liquid has a density of 1,100 kg/m³ and a viscosity of 50 cP (0.05 Pa·s).

Step 1: Reynolds number

  • N = 90 ÷ 60 = 1.5 rev/s.
  • Re = 1,100 × 1.5 × 0.70² ÷ 0.05 = 808.5 ÷ 0.05 = 16,170.
  • This is above 10,000, so the flow is turbulent and Np = 1.27 can be used.

Step 2: impeller power

  • N³ = 1.5³ = 3.375 and D⁵ = 0.70⁵ = 0.168.
  • P = 1.27 × 1,100 × 3.375 × 0.168 = 792 W, or about 0.79 kW.
  • Power per unit volume: 0.79 ÷ 6.28 = about 0.13 kW/m³.

Step 3: motor and gearbox

  • Torque at the impeller shaft: T = P ÷ (2π × N) = 792 ÷ (2π × 1.5) = 84 N·m. The gearbox output must be rated for this torque with the maker's service factor.
  • Assuming a gearbox efficiency of 95%, the motor must deliver 0.79 ÷ 0.95 = 0.83 kW.
  • Seal and bearing losses, a colder and thicker batch at start-up and the normal uncertainty in Np all justify a margin, so choose the next standard motor above 0.83 kW: 1.1 kW.
  • A four-pole motor runs at about 1,450 rpm on 50 Hz, so the gearbox ratio is 1,450 ÷ 90 = 16.1, a standard 16:1 ratio.

Now compare impellers. With everything else the same, a Rushton turbine (Np = 5) would draw 3.12 kW and a hydrofoil (Np = 0.3) only 0.19 kW. The impeller choice changes the power more than any other decision, which is why it should follow from the duty: radial turbines for gas dispersion and high shear, pitched blades and hydrofoils for blending and keeping solids in suspension.

Bar chart of agitator power at 90 rpm with a 0.70 m impeller: Rushton turbine 3.12 kW, four-blade pitched blade turbine 0.79 kW, hydrofoil 0.19 kW

Power drawn by three impellers of the same 0.70 m diameter at 90 rpm in the example tank.

How speed and diameter change the power

  • Speed: raising the example agitator from 90 to 120 rpm multiplies the power by (120 ÷ 90)³ = 2.37, from 0.79 to about 1.88 kW. Torque rises with the square of speed, by 1.78 times.
  • Diameter: a 10% larger impeller (0.77 m instead of 0.70 m) at the same speed draws 1.1⁵ = 1.61 times the power.
  • Density: power scales directly, so a batch at 1,300 kg/m³ instead of 1,100 kg/m³ needs 18% more.

Because the exponents are so steep, check the drive at the highest speed a variable-frequency drive may run it and at the densest, most viscous batch the tank will see, not at the average.

Practical points

  • Use the viscosity and density at the worst operating condition, often the start of a batch or the coldest temperature.
  • On a shaft with two or more impellers, the powers roughly add up when the impellers are spaced well apart; closely spaced impellers draw less in total. Confirm with the supplier.
  • Gas sparged under a Rushton turbine lowers the power it draws, but the motor still has to start and run the ungassed tank, so size it for the ungassed power.
  • Work out the liquid volume and tank dimensions with the tank and vessel calculator, then pick the motor and gearbox with the motor and gearbox selection calculator.
  • Convert cP to Pa·s, or kW to HP, with the engineering unit converter. For a whole plant, see reactors, tanks and pumps for a batch chemical plant.

Check the Reynolds number, take a power number for the impeller you intend to use, calculate the power in SI units, then add the drive losses and a sensible margin. That gives a solid estimate to compare against supplier quotations, and the supplier's own impeller data should confirm the final motor size.

#power number#mixing tank#mixer#impeller#motor sizing#agitator