Sizing a pump motor from flow and head

How the Pump head & power calculator turns flow, head and fluid density into hydraulic, shaft and motor power and the next standard motor size, with a worked example and its limits.

By Site AdministratorUpdated 3 min read

A pump is chosen on flow and head, but the motor you order and the electricity you pay for follow from power. The Pump head & power calculator takes the duty and the fluid and gives three power figures and a standard motor size, so you can check a pump quotation or size a motor before the pump curve arrives.

How the calculation works

You enter flow (m³/hour), total head (metres), fluid density (kg/m³), pump efficiency (%) and motor efficiency (%). The tool then works in this order:

  • Hydraulic power (kW) = density × 9.80665 × flow × head ÷ 3,600,000, with flow in m³/hour. This is the work actually done on the fluid.
  • Shaft power = hydraulic power ÷ pump efficiency.
  • Motor input power = shaft power ÷ motor efficiency. This is what the meter reads.
  • Motor frame = motor input power × 1.15, rounded up to the next standard IEC size in the tool's list, which runs from 0.37 kW to 400 kW.
  • Differential pressure (bar) = density × 9.80665 × head ÷ 100,000.
  • Specific energy = motor input power ÷ flow, in kWh per m³.

Take the tool's default values: 50 m³/h of water (1000 kg/m³) against 30 m of total head, 70% pump efficiency and 92% motor efficiency.

Step
Calculation
Result
Hydraulic power
1000 × 9.80665 × 50 × 30 / 3,600,000
4.09 kW
Shaft power
4.086 / 0.70
5.84 kW
Motor input power
5.837 / 0.92
6.34 kW
Motor frame (with 15% margin)
6.345 × 1.15 = 7.30, next size up
7.5 kW
Differential pressure
1000 × 9.80665 × 30 / 100,000
2.94 bar
Specific energy
6.345 / 50
0.127 kWh/m³
Energy per 24 hours
6.345 × 24
152.3 kWh

Over 30 days of continuous running the motor draws about 4,568 kWh. The tool stops at energy; it does not ask for a tariff, so multiply by your own electricity rate.

Use each figure for its own job. Shaft power, 5.84 kW here, is what the pump coupling and shaft must carry. Motor input power, 6.34 kW, is the basis for running cost. The motor frame, 7.5 kW, is what you order; it is larger than the input power because of the 15% margin, so the motor will not run fully loaded at this duty. Specific energy in kWh per m³ is handy for comparing two pumps or two pipe layouts that move the same water: the lower figure is cheaper to run.

What the tool assumes and leaves out

  • One duty point. It does not read a pump curve, and it does not check NPSH or cavitation.
  • Head is yours to supply. The tool does not calculate friction. Work out line losses separately and add them to the static lift.
  • Density only. The fluid enters through its density, which changes power and pressure. There is no viscosity correction, so a thick liquid needs a derating from the pump maker.
  • Efficiencies are your inputs. The tool hints at 65–80% for a well-selected centrifugal pump, lower at the ends of its curve.
  • A fixed 15% margin. Above 400 kW the size is rounded up to a multiple of 50 kW.
  • No prices. It gives kilowatts and kilowatt-hours, not rupees or dollars. The 24-hour and 30-day figures assume continuous running.

Common mistakes

  • Leaving out friction. Total head is static lift, plus every friction loss between suction and discharge, plus any pressure at the destination. Using lift alone undersizes the motor.
  • Wrong flow units. The input is m³/hour. A flow in litres per second must be multiplied by 3.6 first.
  • Costing on shaft power. The meter reads the motor input power, which is higher.
  • Ignoring density. Water is 1000 kg/m³, vegetable oil 910, milk 1030 and 50% caustic 1520. A heavy liquid raises both power and pressure for the same flow and head.
  • Mixing up head and pressure. The tool takes head in metres and reports pressure in bar. For water, 30 m is about 2.94 bar, as in the example.
  • Assuming the best efficiency everywhere. A pump run far from its best point is less efficient than the 70% typed in.

Run your own duty in the Pump head & power calculator. To find the friction loss to add to the head, use the pipe size and pressure drop calculator, and for a gearbox or drive after the motor try the motor and gearbox selection tool.