Checking pipe size and pressure drop for a liquid line
How the Pipe size & pressure drop calculator turns flow, bore, length and fluid properties into velocity, Reynolds number and friction loss, with a worked example and its limits.
Before a pump is chosen, the line it pushes through has to be sized. A bore that is too small makes the liquid fast, noisy and expensive to pump; one that is too large costs more in pipe and lets solids settle. The Pipe size & pressure drop calculator takes a flow and a bore and gives the velocity, the type of flow and the friction loss, so you can compare bores before you buy pipe.
How the calculation works
You enter flow (m³/hour), internal bore (mm), straight length (m), fittings allowance (% of length), fluid density (kg/m³) and viscosity (cP). With the bore d in metres, the tool works in this order:
- Velocity (m/s) = flow ÷ 3600 ÷ (π/4 × d²).
- Reynolds number = density × velocity × d ÷ (viscosity ÷ 1000). Below 2,300 the flow is called laminar, from 2,300 to 4,000 transitional, above 4,000 turbulent.
- Friction factor (Darcy): in laminar flow, 64 ÷ Reynolds number. Above 2,300, the Swamee–Jain fit to the Colebrook equation, f = 0.25 ÷ [log10(0.000045 ÷ (3.7 × d) + 5.74 ÷ Re^0.9)]², with the Reynolds number held at 4,000 or more inside the formula. The roughness is fixed at 0.045 mm, commercial steel.
- Equivalent length = straight length × (1 + fittings ÷ 100).
- Head loss (m) = f × (equivalent length ÷ d) × velocity² ÷ (2 × 9.80665).
- Pressure drop (bar) = head loss × density × 9.80665 ÷ 100,000.
The velocity is also judged against practice: under 0.9 m/s is slow and solids may settle; 0.9 to 2.5 m/s is normal for a pumped liquid line; 2.5 to 3.5 m/s is fast but acceptable on a short run; above 3.5 m/s is too fast. The tool also shows the loss per 100 m of equivalent length, for comparing routes.
A worked example
Water (1000 kg/m³, 1 cP) at 50 m³/hour through a 100 mm bore, 100 m of straight pipe and a 30% fittings allowance, which are the tool's starting values:
- Area = π/4 × 0.1² = 0.007854 m², so velocity = 50 ÷ 3600 ÷ 0.007854 = 1.77 m/s, which is normal.
- Reynolds number = 1000 × 1.7684 × 0.1 ÷ 0.001 = 176,839, so the flow is turbulent.
- Friction factor from the formula above = 0.0189.
- Equivalent length = 100 × 1.30 = 130 m.
- Head loss = 0.0189 × (130 ÷ 0.1) × 1.7684² ÷ 19.6133 = 3.92 m.
- Pressure drop = 3.92 × 1000 × 9.80665 ÷ 100,000 = 0.384 bar, or 0.295 bar per 100 m.
Try other bores at the same flow. An 80 mm bore gives 2.76 m/s and 1.18 bar, about three times the loss; a 125 mm bore gives 1.13 m/s and 0.126 bar. When sizing the pump, add the head loss (3.92 m here) to the static lift.
What the tool assumes and leaves out
- It treats a single-phase, incompressible liquid. It is not for steam, air or slurries.
- Roughness is fixed at 0.045 mm. Old, scaled or lined pipe will differ.
- Fittings are a percentage of the straight length (the tool suggests 20–50%), not counted one by one.
- Viscosity is one figure, so enter it at the working temperature. Fluids whose viscosity changes with flow are not modelled.
- It calculates friction only: no static lift, pump curve, elevation or valve settings.
- Between Reynolds numbers 2,300 and 4,000 it uses the turbulent formula at 4,000, so treat that band as approximate.
Common mistakes
- Entering the nominal size instead of the internal bore. The pipe schedule changes the bore.
- Using the viscosity at room temperature for a liquid that is pumped hot, or the other way round.
- Judging by velocity alone. A normal velocity on a very long line can still give a large pressure drop.
- Forgetting the fittings allowance, or counting the same bends twice.
- Sizing the pump on static lift alone and leaving out the friction head loss.
- Reading the per-100 m figure as the total loss. It is only there for comparing routes, so use the pressure drop over the equivalent length.
Run your own line in the Pipe size & pressure drop calculator. Then use the pump head and power calculator to turn the total head into a motor size, and the unit converter if your figures are in other units.